Bacterial Endotoxin Test Kit
Description
Gel Clot Endotoxin Assay
Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial
Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule
Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial
Gel Clot Endotoxin Assay
The Gel Clot technique is used for detecting or semi-quantifying endotoxins based on clotting of the lysate reagent in the presence of endotoxin. The minimum concentration of endotoxin required to cause the lysate to clot under standard conditions is the labeled sensitivity of the lysate reagent. Incubate the reaction mixture for a constant period according to the directions indicated on COA (usually at 37±1°for 60±2 min.) Then identify the sample that is positive or negative based on whether an intact gel is formed or not.
Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial
Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial contains 0.2 ml Amebocyte Lysate which is sealed in a standard reaction tube under vacuum condition. For our Single Test in Vial, you could add a sample to the reaction tube directly. This means you don’t need to dilute Amebocyte Lysate at first, and you will decide how many vials use each time to avoid waste. No tube for dilution of CSE is needed. Operation of endotoxin detection by employing our Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial conforms to USP and EP .
Catalog No. | Sensitivity EU/ml | Tests/Vial | Vials/Pack |
---|---|---|---|
G020030 | 0.03 | Single Test per Vial | 50 |
G020060 | 0.06 | ||
G020125 | 0.125 | ||
G020250 | 0.25 | ||
G020500 | 0.5 |
Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule
Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule is the economic type of gel clot single test. The Amebocyte Lysate produced by Bioendo features strong resistance to interference and strong improvement for heat stability, allowing shipping at room temperature. Sensitivity of our Single Test in Ampoule covers 0.015EU/ml, 0.03 EU/ml, 0.06 EU/ml, 0.125 EU/ml, 0.25 EU/ml, 0.5 EU/ml.
Catalog No. | Sensitivity EU/ml | Description | Kit Contents |
---|---|---|---|
GS44010015 | 0.015 | Bioendo™ Gel Clot Endotoxin Test Kit, (Single Test in Ampoule, 44 Tests/kit) | 44 Gel Clot Lyophilized Amebocyte Lysate; 1 CSE 10A; 5 TRW02. |
GS44010030 | 0.03 | ||
GS44010060 | 0.06 | ||
GS44010125 | 0.125 | ||
GS44010250 | 0.25 | ||
GS44010500 | 0.5 |
1.3 Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial
Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial includes 1.7 ml/vial, and 5.2 ml/vial; and sensitivity covers 0.03 EU/ml, 0.06 EU/ml, 0.125 EU/ml, 0.25 EU/ml, 0.5 EU/ml. The Multi-test Vial is available for you when you are doing large-scale Gel Clot assays.
Catalog No. | Sensitivity EU/ml | ml/vial | Tests/Vial | Vials/Pack |
---|---|---|---|---|
G170030 | 0.03 | 10 | ||
G170060 | 0.06 | |||
G170125 | 0.125 | 1.7 | 16 | |
G170250 | 0.25 | |||
G170500 | 0.5 | |||
G520030 | 0.03 | |||
G520060 | 0.06 | |||
G520125 | 0.125 | 5.2 | 50 | |
G520250 | 0.25 | |||
G520500 | 0.5 |